Clamp Meter |
|
|
|
![]() |
|
| |
| WIN-6900
( Basic Model ) |
|
| |
• Display: 2000 counts
• Manual range
• Basic accuracy: 0.5%
• DC Voltage: 200V ± 0.5%, 600V ± 0.8%
• AC Voltage: 200V ± 0.8%, 600V ± 1.0%
• AC Current: 200A ±2.0 %, 1000A ±2.5 %
• Resistance: 200 O ±1.0 %
• Diode Check
• Continuity Buzzer
• Data Hold
• Back light
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
| |
| WIN-6910
(AC/DC Clamp + Temperature) |
|
| |
• Display:
4000 counts
• Auto/Manual range
• Basic accuracy: 0.5%
• DC Voltage: 400mV/4/40/400V ± 0.5%, 600V ± 0.8%
• AC Voltage: 4/40/400V ±1.0 %, 400mV/600V ±1.5 %
• DC Current: 400A ±1.5 %, 1000A ±2.0 %
• AC Current: 400A ±2.0 %, 1000A ±2.5 %
Resistance: 400Ω/4/40/400kΩ/4MΩ ±1.0 %, 40MΩ ±2.0 %
• Capacitance: 40nF ±3 %, 400nF/4/40 µ F ±2.5 %, 100 µ F ± 5%
• Frequency: 10Hz10MHz ± 0.1%
• Duty Cycle: 0.1%--99.9% ±2.0 %
• Temperature: -58°F ~ 302°F±(5°F+2)
302°F
~ 1292°F±(3%+2°F)
• Diode Check
• Continuity Buzzer
• Relative Measurement
• Data Hold
• Back light
• Auto Power Off (can be disable)
|
|
| |
|
|
| |
|
|
| |
|
|
|
| |
| WIN-6920
(AC/DC Clamp + Temperature) |
|
| |
• Display: 4000 counts
• Auto/Manual range
• Basic accuracy: 0.5%
• DC Voltage: 400mV/4/40/400V ± 0.5%, 40mV/600V ± 0.8%
• AC Voltage: 4/40/400V ±1.0 %, 40/400mV/600V ±1.5 %
• DC Current: 400A ±1.5 %, 1000A ±2.0 %
• AC Current: 400A ±2.0 %, 1000A ±2.5 %
• Resistance: 400Ω/4/40/400kΩ/4MΩ ±1.0 %, 40MΩ ±2.0 %
• Capacitance: 40nF ±3 %, 400nF/4/40 µ F ±2.5 %, 400 µ F ± 5%, 4000 µ F ±20 %
• Frequency: 10Hz10MHz ± 0.1%
• Temperature:
-50°C ~ 150°C(-58°F ~ 302°F) ±(3°C+1) ±(5°F+2)
150°C ~ 700°C(302°F ~ 1292°F) ± (3%+1°C) ±(3%+2°F)
• Diode Check
• Continuity Buzzer
• Relative Measurement
• Max/Min Measurement
• Data Hold
• Back light
Auto Power Off (can be disable)
|
|
| |
|
|
| |
|
|
| |
|
|
|
| |
| WIN-6930
(AC/DC Clamp + Temperature + True RMS) |
|
| |
• Display: 4000 counts
• Auto/Manual range
• AC True RMS
• Basic accuracy: 0.5%
• DC Voltage: 400mV/4/40/400V ± 0.5%, 40mV/600V ± 0.8%
• AC Voltage: 40/400V ±1.0 %, 40/400mV/4V/600V ±1.5 %
• DC Current: 400A ±1.5 %, 1000A ±2.0 %
• AC Current: 400A ±2.0 %, 1000A ±2.5 %
Resistance: 400Ω/4/40/400kΩ/4MΩ ±1.0 %, 40MΩ ±2.0 %
• Capacitance: 40nF ±3 %, 400nF/4/40 µ F ±2.5 %, 400 µ F ± 5%, 4000 µ F ±20 %
• Frequency: 10Hz10MHz ± 0.1%
• Temperature:
-5°C ~ 150°C(-58°F ~ 302°F) ±(3°C+1) ±(5°F+2)
150°C ~ 700°C(302°F ~ 1292°F) ± (3%+1°C) ±(3%+2°F)
• Diode Check
• Continuity Buzzer
• Relative Measurement
• Max/Min Measurement
• Data Hold
• Back light
Auto Power Off (can be disable) |
|
| |
|
|
| |
|
|
| |
|
|
|
| |
|
| |
|
|
 |